Air Blow Type DC Static Eliminator KD-410

Order Code : KD-410

Features
- The long blow range of ionized air permits static elimination from a distance as well as static elimination of moldings of various shapes.
- Good ion balance ensures efficient static elimination regardless of the polarity and surrounding conditions of charged objects
- Air volume can be easily adjusted using the fan control knob
- Can achieve well-balanced static elimination. The amount of ozone generated is extremely low.

Specification
Power Source:                100VAC or 200VAC,                    Noise:                                   52dB at 50Hz,
                                             50/60HZ                                                                                       56db at 60Hz
Input Current:                   500mA                                           Ozone Concentration:      0.005 ppm
Power Consumption:      50VA                                              Operation Cond:                Temp. 0 to 40 c,
Air Blow Volume:             5.3/6.3m3/min (variable)                                                          humidity80%max
Fan:                                     Metal blade fan, with filter         Weight:                               2.5kg

Order Code : KD-730B,KD-720B
 
KD-720B
KD-730B
Static Elimination Method
DC Corona Discharge
Electrode Coupling System
High Resistance Coupling
input
12VDC, 260mA
12V, 370mA
weight
Approx 1.25kg
870g
Discharge NeedlePoint Shorting Current
60uA or less(per needle)
Effective Electrorode Length
100 to 500mm.
Protective Circuit
The circuit shall stop the-voltage output and turn off the pilot lamp in the event of abnormal discharge
Cleaning Alarm, High Voltage stop, front panel LED display, Photocoupler output
Air Flow Rate
High / Low
Specifications
Order Code: ITI-02
Major Applications
- Fabrication and Assembly of Electronic Devices
- Removal of static electricity from LCD and PCB
- Optical component dust control

 

 

 

 

 

 

 

 

Air Blow Type DC Static Eliminator KD-730B, KD-720B

KD-730B Feature
- Compact design with planting the emitters direct into the frame.
- Able to install the limited space like the inside of handler machine.
- Inform the time for cleaning with the cleaning alarm lamp in color.
- Output signal terminals for the interface with other equipment.
- Inproving the ionization speed with the high speed fan.
- High reliability with the uniquely design high voltage transformer which generates
the both of positive and negative high voltages only by the single transformer (Japanese Patent Granted)

- Stable ion balance with ion balance control circuitry.
- New tilt lock system prevents from unnecessary tilting with vibration.

KD-720B Features
- Can be safely installed without worrying about induction in delicate devices as no high-voltage wiring required.
- Static elimination can be efficiently achieved with little or no reverse charge.
- Features a lengthy iron irradiation distance which suitable for elimination of static electricity from charged objects in remote places.
- Produces only a little amount of ozone with its high ion generation efficiency.
- Reduce the possibility of electric shock with a current limiting circuit incorporated in the ion generating electrode.
- Involves no swing in surface potential of the charged object

 

 

 

 

 

 

 

 

 

 

 

 

 

Air Blow Type DC Static Eliminator ITI-02

The newly designed fan guard enables quick static elimination even at a distance.

The newly developed D.I.C circuit maintains a constant ion balance and consistant quantity
of generated ions. The frequency of maintenance can thus be significantly reduced. The front
fan guard can be removed in a single motion, facilitating access and maintenance for
electrodes and nearby parts.

At power up, the static eliminator motifies the user when the next maintenance is due.
D.I.C (double ion control) refers to a circuit that controls both the ion balance and the quantity of
generated ions to constantly provide static elimination in the most appropriate way.

 

 

 

 

 

 

Air Blow Type AC Ionizer LFA-03B

Features
- Electrode Needle : Employs inconel, a material generating little dust suitable for class-100 clean room.
- Air direction Fin : An Air direction fin is provided on the front which directs air upward to blow ions to
a distance (up to 1m from the device)
- Fan VR : Flow rate control can be exerted by the volume control provided on the front panel.
- Display and Alarm : The CLEAN BALANCE lamp on the front panel glow green on power turn-on.
If the ion balance is lost or if the electrode becomes stained, the color of the light changes from
orange to red and the alarm buzzer sounds. In the term “CLEAN BALANCE” “CLEAN” refers to the
degree of contamination of the electrode and “BALANCE” refer to the balance of ions.
- Electrode Cleaning : The air direction fin and net can be removed by one-touch simple action for
maintenance.
- Safety Device : The high voltage shall be off when the air direction fin and net are taken off at the
electrode cleaning.

Order Code: LFA-03B